How do I keep my house cool? How can my house cope with climate change? How do I deal with extreme heat?  These are normal questions now. We have old buildings, but new weather.

Climate change impacts all aspects of our lives. It will continue to have far reaching effects on; what plants thrive; what farming is possible; what activities and events are fun; how we sleep and how we travel. Buildings themselves have always had to deal with weather and climate, but this has been a relatively stable characteristic. Buildings can’t move, so are likely to have to be adapted in order to continue to perform as the weather changes around them. The climate and weather has and is still changing at such a speed, that many buildings will need to be altered, retrofitted or fundamentally changed as soon as possible to remain as fit-for-purpose.

This post isn’t going to discuss what needs to be done to slow the effect of climate change, as that is a whole topic in itself, but the building industry and space heating requirements of homes is a huge percentage of the emissions causing change in the atmosphere. Petrochemical, concrete/cement and fossil fuel use are fundamental to that harm. We need to be using less of these. However this short post is about how the changing weather and patterns should and could influence design decisions beyond the general requirement of using less harmful products.

New build work, even basic extensions to houses need to be mindful of the ever less moderate weather and plan for more more extreme and perhaps inhospitable conditions. The building regulations that stipulate levels of insulation, gutter sizes and amounts of glazing are not moving as quickly as the outside climatic conditions so careful considered design ought to be a little proactive.

Looking at traditional structures built around the world, it can be seen how they differ and evolved to suit their climates. This is the joy of vernacular (literally ‘the language’) buildings. Most traditional methods of construction relate to; the available materials, limitations of such materials, or the weather. And usually all three.

Traditional thick-walled earth and mud adobe structures of Africa and Central America keep out the powerful suns rays with their heavy thick walls and small windows, and were built out of an ample resource. The clay soils allowed this kind of structure to be built – solid earth walls are strong when thick, but wont tolerate big openings easily – so another harmonious reason why the windows were small. Whereas the open sided shelters of the island nations let the strong winds though rather than ripping them apart.

Deep courtyards and ‘windcatchers’ of Middle East and Asian ancient towns provide ‘sinks’ or wells to trap the cold night air and form deep shadows before the heat of the next day builds up as illustrated in the wonderful old photos below. The deep courtyards often had openings directed to them, so wind was pulled through and up out of the courtyard like a chimney. Larger courtyards often have water or fountains in them to benefit from the cooling effect of water. Roman villas made use of this effect in their layout too.

Hot climate vernacular

Closer to home, steep roofs and overhangs protect from European rain and snow in the mountains. These are extreme ends of the climatic spectrum and its influence but as climate proves to become more extreme or varied, we need to double down on learning from these traditional, simple physics solutions, and perhaps look further afield to more extreme climates for inspiration.

Devon cob walls (mostly earth) need to be protected from rain more than those earth structures in the photos above as we live on a wet island, so big overhanging thatch roofs ensured water dripped beyond and didn’t splash the walls. But go to neighbouring Cornwall or Scotland and the eaves have to be tightly clipped to the building to prevent strong winds ripping them off. Cornwall didn’t really have good reeds for thatching, but did have slate mines, so slated the roofs and built the walls out of stone rather than mud. Upland Britain like the Lake District and Scotland had similar roof designs to Cornwall due to their strong winds too. In Norfolk and the east where wind-driven rain is a rarer occurrence the roof pitches are shallower and use roman pantiles rather than slate which isn’t found there. If you use pantiles at a shallow angle in exposed Cornwall, chances are they’ll be ripped off or leak all the time. However if stronger winds are more frequent and storm intensities increase, the localised, regional designs of old may also need to change too.

The Approved Documents of the building regulations literally has a page with simplified exposure zones mapped out based on the “British Standard BS 8104:1992 Code of practice for assessing exposure of walls to wind driven rain”. Similar data sets are used for calculating gutter sizes and roof design. ‘BS8104’ is the identifying number for the British Standard document, but the ‘1992’ bit is the year of release. This is at least 3 decades old in perhaps the most rapid climatic change since we’ve lived in cities and houses. There are some more recent updates in BS5628 (2001) but the 1992 data is still used. Clearly this is out of date and we need to be more considerate of storms, temperature and robustness of building design. Unfortunately the building regulations generally set out the minimum standard for construction, and few go beyond them. Most construction projects do not have the budget to make the ‘right’ decision about every aspect of the build to go beyond the minimum standards. When clients have to weigh up if they can choose a different kitchen door style, or pay for guttering and insulation above and beyond what is ‘standard’, the balanced approach typically prevails.

UK exposure zones from part C

Sometimes a planning department may include some specifics on construction, typically getting involved with soakaway design, stating it needs a climate change factor to prevent flooding. Recently one such condition on a planning approval required a 10% increase on the drained area being measured, and then a 45% extra capacity on the soakaway design in the ground. While a good idea to improve on the minimum standards, arbitrarily adding to a planning condition seems to be in the wrong place to be considering complex construction detailing, and is being applied haphazardly. Additionally it requested the soakaways to be designed to a set of standards normally reserved for large scale developments (BRE365) rather than the simpler normally adopted method set out in the approved documents of the building regulations. Without specialist water bowsers and complex calculations working out a simple soakaway becomes highly specialised and fraught with risk and cost. This is frustrating the system and processes we have, as the planning department generally do not have construction or building regulation experience, yet are getting involved and causing difficulties outside of their arena later down the line when they are no longer involved. It is also seemingly random which projects get such a treatment, there is no nationalised criteria so it is becoming impossible to predict. Far better would be to have the building regulations updated for every single building project.

Rainwater gutter sizing also relies on this historic climate data, based on weather data across the UK, and with a safety factor added in. The safety factor helps but it still feels like an afterthought. If the volume of water raining remains the same, but it comes down in a much shorter period of time, like our winter now storms are, then clearly these calculated gutters may struggle and be overtopped potentially causing damage to other parts of the building if repeated over a winter season. Clearly guttering being overtopped is a trivial event compared to flooding disasters, but I am using it as an example of how much impact into every design decision this will have. If a new timber framed extension is built (to use less concrete) but the guttering cannot cope, then repeated wetting may damage the structure and insulation beyond repair, leading to inefficiency or lasting damage. Buildings need to be long-lived to make the large amounts of embodied carbon and environmental impact of them tolerable. A super energy-efficient building that falls apart after ten years is no good whatsoever.

Excessive heat gains of buildings are beginning to be controlled through the building regulations, but only currently for new homes and not really to a high enough standard. It is worth saying again just in case it isn’t understood, is that the term ‘Global Warming’ does not mean nicer weather. The global weather system is incredibly complex and our own little part of the world here in Devon has overlapping dynamic systems that influence what we feel day-to-day. As this is changing we are experiencing more extreme weather, including more heat waves, drier periods, faster rainstorms and winds. Not necessarily disaster-movie levels of chaos, but even simple buildings have been finely tuned on decades of development based on historic weather information. If that weather has dramatically altered then the buildings are less able to cope. This summer of 2026 saw air prolonged temperatures of 35˚ in Exeter and it was the rare few buildings that managed to keep that heat at bay after a week or so.

The point here is that buildings being built ought to be considerate to the more extreme weather and minimum standards really are no longer be sufficient. It should therefore be worthwhile specifying or making design choices historically reserved for more extreme locations.

Each building project should consider the following areas alongside any possible reduction on petrochemicals, concrete and applying suitable sustainable energy sources:

Shade.

Such a basic but fundamental part of keeping the heat off in summer heatwaves. Larger glazed areas are great, but if the sun blazes on them, the room will soon overheat. Overheating controls have been introduced in Part O of the building regulations but are currently only applicable for new-build development. In Part O shade has to be permanent part of the building – planting cannot be counted. Having said that a deciduous tree is a great shade-maker and relatively easy to retrofit. It blocks the suns rays, evaporates heat away and loses its leaves in winter when you want the sun to pass through into your room. Pull out awnings definitely also have their place as a temporary method of keeping windows in shade but rely on a bit of manual operation. Shading the glass from the outside is far more efficient than on the inside once the energy has passed through the glass and into the room’s air. External shading also allows you to operate the window fully for ventilation while in shade – something internal blinds or curtains don’t let you do as they block the path of air.

Night-time cooling.

If you can leave windows open at night you will be able to purge all the hot air and critically also help cool down the structure itself, which after a day’s heat gains will be emitting warmth back into the room and can build up over several days. Fashionable huge sliding doors are not ideal for leaving open as unwanted people, animals etc can gain easy access. Making sure there are windows alongside any doors allows for a more secure opening overnight, likewise rooflights are relatively secure as they are harder to access. There are lots of examples of older buildings in cities I have seen abroad that have decorative bars on the outside, with inward opening windows for night time cooling. Thinking along these lines for new development with something like louvres might be a practical way to achieve both shading and secure night-time cooling.

Glazing.

Very much linked to shade and night-time cooling above, but there are options with the windows themselves. Firstly, more glass is not always better. Also the big opening doors are fine if you are in, but you cannot always open them when cooler weather prevails – eg wide open overnight. Carefully positioned rooflights are less of a security risk and can let in softer north light. Some security or safety devices on windows limit opening widths of windows which can mean there is not enough ventilation. Opening the window and then closing the blinds or curtains might prevent good airflow. (only useful if it is cooler airflow). There are various coatings available on glazing. From semi-reflective or heavily tinted, physical dots ‘fritted glazing’, through to more subtle or near-invisible, you can alter the total heat transfer through the glass. Some heat will be reflected off, some will be absorbed by the glass itself (and radiate into the room) and some will penetrate right through. This is often expressed as the g value of the glass which is basically a percentage figure of transmission – the lower the number, less heat will penetrate.

Thermal mass.

Modern British lightweight (can I say flimsy?) houses do not have enough dense materials in them. Dense materials like stone, concrete, clay, wood fibre and some man made boards all have high specific heat capacity. Eg they take loads of applied heat before they get hot. This means they take longer to get warm, if the nights are cool, you can cool them down again overnight (remember the windcatchers and courtyards above?) so they are ready to go again in the morning. A lighter-weight structure may well only last a few hours in blazing sunshine before it is at capacity and radiates heat into the rooms. It is this rapid yo-yoing that makes them uncomfortable. They do respond quickly to turning the heating on in the winter though but can be a bit volatile in temperature. Think of how cool an old church is in summer. It has small windows, and masses of high thermal mass. Seal the warm air out with the doors closed and the sun will take ages to heat it up.

Thermal Insulation.

Thinner insulation products are almost all made from petrochemicals. These are bad in so many ways, but provide the greatest u-value for the thickness (excluding specialist vacuum products). But if you read the thermal mass paragraph above you will realise they are very lightweight compared to a mineral wool quilt or wood fibre which will add to the overall heat barrier your walls can form. The more natural products such as wood fibre, sheeps wool etc can also help regulate the room’s humidity and keep things stable. They do need much greater care in detailing and design though.

Rainwater.

Guttering and downpipes need to be able to cope with rapid storm volumes. Better yet, the system should be designed to hold back some of the water on site. This could be as basic as a soakaway under the garden, or more obvious such as green living roofs or water butts, ponds etc. The national sewage pipes are often at capacity, and transporting and treating rainwater is not a good use of the pipe network. Permeable paving and landscaping designed to cope with sudden varying water volumes all help with this. Building regulations stipulate that any new roof area drains to sustainable methods unless technically not possible on site.

Green living roofs.

These help in so many ways. They add thermal mass to the roof, they add culumative microshade and evaporation off the roof, they provide sound insulation, can prolong the life of the roofing membrane, hold rainwater out of the sewer system and give a bit of habitat. They can be of a low-growing gravel based sedum type plant or as full as a wildflower meadow. When they are wet and holding onto all that water they can be substantially heavy and so the roof needs to be designed to support the weight.

Planting and Landscaping.

Not to be forgotten, the garden spaces can benefit the building just as a green roof can. They add shade, water storage, evaporation, enjoyment and can help with cooling.

As a different topic there are other ways to reduce the impact of the building itself, rather than just the function and conditions, through Microgeneration, Fossil Fuel usage (solar, wind, storage, heat pumps etc), and considering the embodied Carbon, Carbon Footprint and Life-Cycle Analysis of the structure and fittings.

Limiting internal gains

Not really an architecture issue, but people, electronics, lighting, cooking, and bathing all add measurable heat load to the building. People’s bodies kick out around 100W of heat just by sitting, lights left on, hidden transformers for chargers, tvs, smart speakers, all add to the household’s warmth. Individually it is not that significant, but add them all together over a daily cycle and it can make quite a difference. Just go touch your tv screen or that laptop transformer under the table and see what I mean. Turning stuff off properly will help keep things under control.