What is a u-value? How much insulation does my extension need?
A u-value is a way of measuring the heat transmittance through a material, usually a part or element of a building. Buildings in the UK are controlled through the Building Regulations which are divided into separate parts. Part L of the building regulations relates to the thermal performance of the building which is where u-values are most relevant. For a new dwelling compliance with the regulations involves whole-house calculations determining heat losses and gains, which are then compared to what is actually achieved on-site. Part O (overheating) and Part F (Ventilation) also play a factor in these calculations.
On existing buildings the approach is rather more simple. The approved document Part L (generally the accepted norm for compliance with the Building Regulations) requires a basic minimum standard for each separate element, roofs, walls, windows etc.

These minimum standards for existing dwellings are subdivided into two categories:
-
- New thermal elements in an existing dwelling
and
-
- Retained thermal elements in an existing dwelling
For new fabric elements (Such as the walls, roof, floor and windows & doors to an extension), these are set at a single u-value for each.
New thermal elements such as a extensions have to meet the following minimum standards (taken from the 2023 amended Part L AD table 4.2), don’t forget, the lower the u-value the better the performance:
-
- Roofs 0.15 W/m2K
- Rooflights 2.2 W/m2K
- Walls 0.18 W/m2K
- Windows 1.4 W/m2K
- Doors 1.4 W/m2K
- Floors 0.18 W/m2K
Retained thermal elements being renovated however have a two-step process. If the existing performance is worse than a minimum threshold, then upgrade is required, if it is better then it is not compulsory to upgrade. (taken from the 2023 amended Part L AD table 4.3):
-
- Roof threshold 0.35, if worse then upgrade to: 0.16 W/m2K
- Wall cavity insulation 0.70, if worse then upgrade to 0.55 W/m2K
- Wall internal or externally insulated 0.70, if worse then upgrade to 0.30 W/m2K
- Floor 0.70, if worse then upgrade to 0.25 W/m2K
These upgrade figures also apply when there is a change of use or change of energy status. For example when an unheated garage is converted to a habitable heated space or a non-residential building is converted to a dwelling.
However, there are a few caveats to come with this broad rule. For example if it is not ‘technically or functionally feasible’ or would take more than 15 years to payback, then a lesser value can be proposed, but it does has to be justified as thus. There are also lesser standards acceptable on historic or Listed buildings. These upgrades are only applicable to thermal elements that are being ‘renovated’ which is defined in Part L as having a new layer (such as rendering or cladding, dry lining), or having a replacement layer through stripping down to bricks or joists etc and then rebuilding. Replacing the waterproofing layer on a flat roof or adding cavity wall insulation are also triggering activities. The regulations are only applied when such renovation works take place, so if you are not altering the element, it does not need to be upgraded.
If partial works are being done to an element, but to more than 50% of it, or the works amount to 25% of the whole building surface area, then also, the whole thermal element needs to be upgraded too at the same time to meet these renovation performance criteria (table 4.3). Eg, if you are renovating more than half a wall, then the whole wall needs to be upgraded.
If the existing thermal element is to be entirely replaced, then the higher performance of Table 4.2 is simply applied as this is now considered a ‘New thermal element’ – this includes windows and doors as you will note they are absent from the renovation figures.
GLAZED AREAS
As this ‘elemental method’ is rather simplified compared to the modelling calculation required for new dwellings, it also has a maximum glazed area figure to prevent excessive heat losses and gains. (These are meant to be factored-in when the design is modelled.) Note the big difference between an insulated wall or roof compared to the u-values of glazed windows and doors. Even the best triple glazed window will have a considerably worse u-value than a basic insulated wall so this needs to be balanced.
You can imagine an extension that is all made out of glass at a u-value of 1.4 is not going to perform very well in either winter or summer compared to a wall with a u-value of 0.18 (The window has a u-value nearly 8 times higher:- Remember the lower the u-value, the better the performance). Those of you who have used conservatories can vouch for this, but also note conservatories are excluded from the building regs requirement for this very reason. To be exempt they are not allowed to have heating, and they have to have an external-grade door between them and the heated parts of the house, if that door is removed, or they have heating then they should be compliant with the extension criteria above.
According to the approved document Part L, the glazed area of an extension must not exceed 25% of the extension floor area and, the total surface area of any previous windows/doors now lost due to the extension, added together. So for example if you are building a 30m2 extension on the back of your house, and the old patio doors and kitchen window add up to 4m2, then the allowable glazing in the extension will be: 25% of 30m2 (7.5m2) plus 4m2 so a total of 11.5m2 of new glazing allowed.
Often more interesting architectural solutions demand more glazing than this, so there are two options to adjust the figures and secure consent. One would be to have a SAP calculation carried out, to determine the losses and gains of the whole building, and recommend any upgrades elsewhere to balance out the greater glazed area.
Or if more simple in nature or otherwise preferable, an area-weighted calculation of just the extension can be submitted as part of your building regulations submission by your architect. This basically adds up all the areas and u-values of a perfectly compliant design with smaller glazed areas as the “notional design”. Going through the multiplication formula of areas and u-values given in AD PartL, this creates a total ‘notional design area-weighted total’. Now duplicate this equation but increase the glazed area to what is desired, eg exceed the 25%+lost windows figure. This will create a worse total, but by adjusting the u-values in other areas to be better, this worse total can be offset elsewhere until it matches or improves over the the notional design. For example, adding a bit more insulation to the floor and roof might offset the increase to glazing area, or upgrading the glazing to triple glazing to improve above the minimum standard of 1.4 might offset sufficiently. As long as no single element is worse that the threshold levels in table 4.3 you can tweak these figures to provide solutions to non-standard issues other than glazed areas too (for example not being able to fully meet wall insulation levels, you could bump-up the floor levels to compensate). Due to the limited areas involved this is hard to carry out on smaller extensions with lots of glazing.
DRAWBACKS OF A SIMPLIFIED SYSTEM
Only meeting minimum u-value standards is perfectly plausible and will be compliant when working on an existing building, however; Quality of workmanship and junctions (leakiness); Repeat cold-bridges (where for a brief moment the u-value is worse, but regularly repeated over a whole structure, eg where a joist passes through insulation); Resistance to summer solar heat gains, are also all significant issues in buildings and not addressed by solely focusing upon u-values.
The airtightness of a building will make a huge impact upon the actual performance. Having masses of insulation is only any good as long as the air cannot bypass it all through a gap at the edges. Draught-sealing has long been the most cost effective way of reducing your home’s heatlosses and remains so. However, small hidden draughts between construction gaps and junctions are hard to find and resolve, especially if they lie deep within the construction build-up. This is why new build construction uses wind-tight membranes and sealing tape, effectively like sealing the building in wrapping paper. New dwellings are also ‘pressure tested’ to see how leaky they have been built, and this is compared against the design and scored. Builder’s will have to meet a minimum score or rectify on site before sign off. On site, they literally use a massive front-door shaped fan to try and suck all the air out of the building, and see what pressure they can measure at the fan. This isn’t required on existing buildings (yet) but most of the best retrofit projects and certainly all PassiveHaus and EnerPhit projects undertake one voluntarily to better understand their buildings. On exemplar retrofit projects a pressure test is undertaken at the outset, and with a thermal camera to highlight the leaks that glow brightly on the camera when the air pressure forces heat out through the gaps. From this, targeted action can be taken and any ventilation and glazing systems can be designed to the correct level.
Methods such as PassiveHaus take things further than Part L and demand an incredibly air-tight construction, really signing up to the mantra “Build tight, Ventilate right”. (Controlled intentional ventilation is a different issue compared to the leaks in an external envelope of the building).
Cold bridges are also controlled on new buildings but are much more relaxed on existing and extensions. However even the wooden rafters are now considered a sufficient cold-bridge compared to the levels of insulation required now in roofs, so minimum standards tend to dictate the use of an insulation between rafters and another insulation layer either over or under them to form a continuous layer without being fully penetrated by a piece of timber.
Summer solar gain (The degredation delay – or how fast the heat travels through the insulation) is a complex issue, but noteworthy as modern lightweight insulation products (Those yellow, foil-faced boards that look like fancy polystyrene) are great at retaining the warm air inside our rooms but not very good at preventing the penetrating heat of the summer’s sun. Natural fibres or heavier products such as woodfibre or rock based quilts perform much better in this regard (and don’t have such high petrochemical content) although will come with a greater thickness ‘penalty’ if just comparing u-values. The always-helpful folk at BackToEarth in Silverton have a great article on the effects of summer sun and explain it better than I can, head over here for more info. Additionally the much heavier wood fibre boards offer improved acoustics and winter internal environment for homes, offering more stable central heating demands, reducing temperature and humidity swings (works well with heat-pumps too!)
This is an introduction to a broad and relatively complex subject, certainly with overlapping considerations, but is intended as an introduction for people considering building or renovation works to their own homes, especially when glazed areas or existing constructions create additional considerations.
If you have a project in mind, or any questions do get in touch.